| Quenching the Thirst of Power Hungry Data Centers |
|
|
| Written by Rick Cockrell | |
| Tuesday, 26 May 2009 | |
|
The extraordinary amount of water consumed to cool today’s data centers is poorly understood at best and largely overlooked at worst. And as data centers continue to grow in size and consume more megawatts of power each year, water supplies are being seriously threatened.
According to the U.S. Geological Survey (USGS), 40 percent of the water used in the United States is for power production followed by the public sector, which taps into 12 percent of the available supply that also includes water used at data centers. See Figure 1.
As data centers are forecast by the EPA to double their cumulative power and water consumption levels by 2011 and every five years thereafter, the industry faces a legitimate and daunting question: is there enough water supply to support the energy needed for power hungry data centers? Historically, water use has been seriously overlooked when designing and permitting a data center. Given the total sustainability footprint that data centers leave behind, the industry is now at a tipping point with respect to implementing new solutions that can reduce energy and water consumption significantly. To understand the magnitude of the water consumption problem in data centers, consider the following. If you take a typical 2.0 Power Usage Efficiency (PUE) rating at a 1mW facility, conventional thinking assumes the water use will be limited to humidifiers and HVAC equipment. These assumptions are seriously flawed. A 1mW facility uses 17,520,000 gallons of water at the power plant annually. If this facility were improved to a PUE of 1.29, the water use could be reduced to 11,300,400 gallons per year. And a PUE of 1.19 could reduce this consumption to 10,424,400 gallons a year. These metrics are not the product of wishful thinking. Recently, Google showcased a 1.25 PUE waterside economized facility; Fortune Data Centers are just completing a 1.38 PUE waterside economized facility; and Sonic.net, an ISP and co-location provider in Santa Rosa, Calif., recently completed a facility retrofit sporting a lean 1.29 PUE refrigerant side economized system. While these efficiency levels are impressive, some industry experts believe obtaining a 1.18 to 1.19 PUE facility is very possible, without compromising any environmental standards. See Figure 3.
Meanwhile, there is an ongoing debate at the facility level that air-cooled systems have achieved “good enough” status to achieve adequate water savings. However, according to most experts in chiller technology, an air-cooled system uses 20 percent more energy than a water-cooled system. Air-cooled chillers in general use more energy than water-cooled chillers due to the differences in most manufacturers’ design condensing temperatures. Consequently, if a 2.0 PUE data center transitioned from an air cooled to water cooled chiller, it could realize a 1.83 PUE.
It is important to recognize that data centers use water at two places; at the facility level and the power plant. According to the Baltimore Air Coils Company condenser handbook, a water-cooled chiller uses a minimum of 2.31 and up to four gallons per minute (GPM) of water per 100 tons of cooling at a 1mW facility (142 ton) chiller load. Despite the fact that water-cooled chillers use more than two million gallons of onsite water drawn from the public sector annually (depending on cycle rate and tower treatment) for the cooling towers, they still reduce aggregate water consumption compared to air-cooled chillers in California. That said, simply changing from an air-cooled chiller to a water cooled chiller is not enough to save water in all applications, due to the energy and water use at the power plant. Each facilities energy and water use should be evaluated on a state-by-state, site-by-site basis. In data center facilities in California, the issue of water consumption is even more precarious. According to NREL, California uses 4.64 gallons of water to produce 1kWh of energy, due to its use of hydro-electric power production. Consequently, for the 1mW facility in California, this equates to more than 40 million gallons of water used at the power plant each year. The change from an air-cooled chiller to a water-cooled chiller in California would result in a 5.2 Million gallon aggregate water reduction. Based on these revealing statistics, data center managers should be highly motivated to investigate how to cut down their PUE levels, not only to curtail power consumption but the water required to cool their IT infrastructure. From a best practices perspective, consider a recent report put out by Google that suggest its new data center averages a PUE of 1.25 annually. For context, lowering data center PUE’s in the U.S. from 2.0 to 1.25 could save on average 45 billion gallons of water annually and 22 billion kWh of energy. And according to the EPA, this PUE drop could eliminate 9,000,000 metric tons of Co2 annually.
This points to numerous sustainability issues facing data centers. As an industry, serious thought must be put into every aspect of making data centers much more efficient in view of the fact they are fast becoming the largest industrial energy user in the United States. About the Author
Set as favorite
Bookmark
Hits: 2101 Comments
(0)
You must be logged in to a comment. Please register if you do not have an account yet.
|
| Fri, Feb 26th, 2010, @8:00am |
| Thu, Mar 11th, 2010, @8:00am |
| Wed, Mar 17th, 2010, @9:30am |
| Tue, Mar 23rd, 2010, @8:00am |
| Tue, Mar 23rd, 2010, @8:00am |
| Mon, Apr 19th, 2010, @8:00am |
| Wed, Apr 28th, 2010, @8:00am |
| Mon, May 17th, 2010, @8:00am |